Products
Where Quality Builds Trust

Smart Gas Meters

gas-rf-
Split Type STS Prepaid Gas Meter - LoRa
prepaid step-tariff data-security data-record anti-magnet alert

Split Type STS Prepaid Gas Meter with AMR/AMI function can realize prepayment function and remote semi-automatic/automatic meter data collection through integrated LoRa RF wireless Comm. Module inside. For Prepaid Function, it complies with International STS Standard IEC 62055-41,51 and gets the STS certification. Customers can purchase gas through multiple methods (Vending Points, Agency, Customer Self-service, etc.), and obtain a 20 digit recharge token. By inputting the recharge token through Customer Interface Unit (CIU), the Gas Meter will be recharged successfully.

Features

AMR Functions
Meter Installation Location (GIS) info. Collection
Meter Reading Task Download from LAPIS Server
Meter reading path optimization
Automatic Meter Data Collection and upload
Remote Meter Valve Control
AMI Functions
Automatic Meter Data Upload
like Hourly/Monthly Consumption Data Record, Battery, Voltage, Meter Alarm Event etc.
Automatic Real Time Clock (RTC) Calibration
Real Time Communication, Remotely Control Valve Open/Close

Massive Data Storage
10 years' Hourly/Monthly Consumption Data Record
Meter Event Record during whole meters' lifespan, such as meter re-start, valve operation failure, magnetic interference, etc.
Anti-magnetic interference
If external magnetic interference happens, the meter shall close the valve and record this event with exact time and event type.
Low Battery Detection & Warning
2 Levels of Low Battery Warning
Data auto-save & Valve Close when battery low

Basic Working Process
Technical Parameters
Smart Meter Specifications
Items Parameters
Nominal Flowrate (Qn) m³/h 1.6 or 2.5 or 4.0
Maximum Flowrate (Qmax) m³/h 2.5 or 4.0 or 6.0
Minimum Flowrate (Qmin) m³/h 0.016 or 0.025 or 0.040
Maximum Pressure Loss (Pmax) Pa ≤ 200
Working Pressure kPa 0.5 ~ 50
Working Temperature ℃ -10 ~ +55
Storage Temperature ℃ -20 ~ +60
Relative Humidity %RH ≤ 93%RH
Cyclic Volume dm³ 1.2
Permissible Error Qmin ≤ Q<0.1Qmax ±3%
0.1Qmax ≤ Q < Qmax ±1.5%
Max. Reading of the Counter m³ 99999.999
Pulse Equivalent m³ 0.01
Case Material Aluminum Body/Steel Body
Protection Level IP66
Power Supply V Lithium Battery DC3.6V
Battery Lifespan ≥ 6 years
Shape and Installation Dimension
gas-sts
Integrated Keypad STS Prepaid Gas Meter
self-service reminder lcd data-query overdraft anti-magnet 10-years

Integrated Keypad STS Prepaid Gas Meter, with a TOUCH KEYPAD on the Meter Case for Meter Recharge & Data Query, conforming to STS Standard IEC 62055-41,51 and is certified by STSA (STS Association). Gas purchase could be done in multiply ways like at LAISON Vending System, Mobile Vending POS or SMS via customer self-service. Additionally, the client can choose IR PAD as an option to recharge the Token, which is suitable for customers whose installation location is relatively hidden and not easy to touch.

Features
Gas Meter Features
  • - Various ways of gas purchase: at vending points by cash, appointed vendor by POS, or customer self-service by e-payment (Mobile Money, Online Bank, etc.).
  • - Audible & visual alarm in predefined cases for gentle reminders, such as insufficient gas credit, low battery, etc.
  • - Full backlight on the meter's LCD, making it easily readable even at night.
  • - Easy inquiry of last time recharge gas volume, remaining gas volume, total consumed gas volume, valve status, low battery, etc., by entering a 2-digit query token.
  • - Emergency gas: customers can still consume gas even if the balance credit is used up, if the overdraft function is activated.
  • - If external magnetic interference occurs, the meter will close the valve and record the event with the exact time and type of event.
  • - 10 years' data record storage.
Basic Working Process
Technical Parameters
Meter Specifications
Items Parameters
Nominal Flowrate (Qn) m³/h 1.6
Maximum Flowrate (Qmax) m³/h 2.5
Minimum Flowrate (Qmin) m³/h 0.016
Maximum Pressure Loss (Pmax) Pa ≤ 200
Working Pressure kPa 0.5 ~ 50
Working Temperature ℃ -20 ~ +50
Storage Temperature ℃ -30 ~ +60
Working Humidity %RH ≤ 93%RH
Cyclic Volume dm³ 0.9
Permissible Error Qmin ≤ Q < 0.1Qmax ±3%
0.1Qmax ≤ Q < Qmax ±1.5%
Max. Reading of the Counter m³ 99999.99
Pulse Equivalent m³ 0.01
Case Material Aluminum Body
Protection Level IP68
Power Supply V Lithium Battery DC3.6V
Battery Lifespan ≥ 6 years
Shape and Installation Dimension